Line bushings


Aufbau
LBCON cable connector



LBCON Ethernet connector
 

 

 

 

General information

Line bushings are used to electrically connect equipment in potentially explosive atmospheres. The connection is always made between a flameproof enclosure (Ex-d) and an enclosure with a different type of protection in accordance with IEC/EN 60079-0.
A special solution is the LBCON. Here the cable bushing and connection Ex e enclosure were combined. The main advantage of this type of connection is the contacting without opening the flameproof enclosure. The LBCON can be opened by screwing off the Ex e sleeve. The contacting is realized via a terminal block of 3, 5 poles as well as 8 poles for Ethernet. Alternative our certified shrink system can be used.

Technical data

Voltage:                          max.400V
Current:                          max.20A
Wire gauge:                    max. 2.5mm²
Temperature range:       -55°C…+115°C (depends on type)
Max quantity wires:          5 wires/8 wires Ethernet
Thread size:                     M20 (3 Pole); M25 (5 Pole)
Material:                          nickel plated brass(other materials on request)
Standardwire material: RADOX 125 (others on request)


If you want to make an inquiry, use the beneath input lines, please.( Length of wires is length on Ex d side; the input uses your installed E-mail program)

;

Quantity of wires

Wire gauge 

Wire length[mm]


Your name:

Your company: